PLC Kinco K304-14AX
PLC Kinco K304-14AX
- CPU: 16-Bit Industrial
- Execution Speed:
Typical Bool Instruction Time: <1μS
Word Operation Time: <96μS
Arithmetic Operation Time for Integers: <130μS
Arithmetic Operation Time for Floating Points: <300μS
- DI Points 8XDC24V
- DO Points 6XDC24V
- User Program Memory EEPROM, 8KB
- Program Backup Permanent Storage, Without the Need of Battery//1000 Instructions
- Memory Area Variable Storage Area (V Area): 2KB
System Storage Area (SM Area): 300 Bytes
Internal Storage Area (M Area): 32 Bytes
- Data Retention Characteristic Configure with the Programming Software: V Area, C (Counter) Area
- Retention Mode and Period Adopt super capacitors and support a retention period of not less than 144 hours upon power failure under normal temperature.
- Data Backup Characteristic Perform Backup Operations VB1648 ~ VB1775 According to User Instructions, 128 Bytes in Total
- Backup Mode and Time EEPROM (Writing Operation for 1 Million Times) Permanent Backup
- Floating Points Supported; the Whole V Area can be Used for Floating Points
- Programming Language Supported Ladder Drawing (LD), Instruction List (IL)
- Instruction Set Basic Instructions: 55; Expansion Instructions: 251
- PasswordProtection Yes
- Max I/O Number Digital Data: 14 in Total (DI8, DO6);
Analog Data: None
- Counter 64
- Operation Mode of Counter Addition, Subtraction
- Counter Range -32768~32767
- Counting Value Retention Function Yes
- Timer 64
1 ms time Base: 4
10 ms Time Base: 16
100 ms Time Base: 44
- High speed counter 2 Single/Dual-Phase High-Speed Counters
Where, Single-Phase Counter with a Maximum Frequency of 20KHz
Dual-Phase Counter with a Maximum Frequency of 10KHz
- Pulse output
2, PTO (Pulse Train Output)/PWM (Pulse Width Modulation Output);
Maximum Output Frequency: 20 KHz(Note: the elay output CPU does not have high speed pluse function)
- Analog Potentiometer -
- Interrupt function Timing Interruption: 2, 1ms Resolution;
Timer Interruption: T2/T3, 1ms Resolution;
Edge Interruption: 4, Rising Edge or Falling Edge Optional;
High-Speed Interruption, Communication Interruption
- Real-time cholck 0
- Number of Connectable Expansion Modules -
- COM Port 1, RS232 or RS485;
Supported Working Modes: Programming, Modbus-RTU (Slave), Free Protocol
- Equipment Connected with COM Port RS232/RS485: PC (For Programming), Third-Party HMI Panel, Third-Party Serial Communication Equipment (For Example, Instruments, Bar Code Reader, etc.)
- Input Power Supply AC85~265V
- Sensor Load Power Supply DC24V, Max. 300 mA
- Dimensions (L*W*H) 97X114X70mm